Development of a biosafety level-2 facility for irradiation of biological cells using MeV ions
text
Jay D. Dias Naresh T. Deoli Deborah Rogers Armin de Vera Karen M. Smith Robin Schmeider-Broussard Harry J. Whitlow
The development of a facility for irradiation of murice and primate tissue presents several challenges. First, extremely low fluences (10⁶-10¹¹ ions cm⁻²) are required to deliver doses of 1 mGy - 50 Gy using MeV proton. Second,the tissues, particularly from non-human primate, may be infectious to humans. Third, protection of irradiated tissue samples from contamination by mold and bacteria is critical. Here we present an ultra-low flux irradiation facility and associated fluence control for biological cell and tissue irradiation under sterile biosafety level 2 (BSL-2) conditions suitable for use with low energy (1-3.4 MeV) protons. The operation is demonstrated using murine astocytes.
Submitted 9 February 2019, Received in revised form 28 February 2019, Accepted 4 March 2019
https://doi.org/10.1016/j.nimb.2019.03.002
Ultra low-flux irradiation MeV ion microprobe Tissue irradiation Biosafety Murine astrocytes